User’s Guide
MultiView™ Series
Digital MultiMeters
Models:
MV110
MV120
MV130
Vedere la pagina 0
1 2 3 4 5 6 ... 12 13

Sommario

Pagina 1

User’s Guide MultiView™ Series Digital MultiMeters Models: MV110 MV120 MV130

Pagina 2 - Hotlines

Operation General Procedures 1. Apply power via ON/OFF switch. If the low battery symbol appears, replace the battery. 2. Set the function switch t

Pagina 3 - Introduction

Diode Measurements 1. Connect the black test lead to the COM-socket and the red lead to the VΩ socket. 2. Set the rotary switch to the "Diode&

Pagina 4 - Safety Precautions

Continuity Measurements (Remove power or voltage from the device under test) 1. Connect the black test lead to the COM-socket and the red lead to th

Pagina 5 - Specifications

Temperature Measurements (MV-120 only) 1. Insert the type K thermocouple mini-connector into the "K" socket. 2. Set the rotary switch to

Pagina 6 - Electrical Specifications

 Tech Support Hotlines 781-890-7440 ext. 200 [email protected] www.extech.comWARRANTY EXTECH INSTRUMENTS CORPORATION warrants this instrument to be

Pagina 7 - Ω range: <75%

Introduction Congratulations on your purchase of Extech model MV-110, MV-120, or MV-130 digital multimeter. Properly used, this meter will provide ma

Pagina 8

Safety Precautions 1. WARNING: Improper use of this meter can cause damage, shock, injury or death. Read and understand this users manual before ope

Pagina 9 - Description (MV120 pictured)

Specifications General Specifications Display 1999 count 3 1/2 digit, adjustable angle (MV-110, MV-120) 19999 count 4 1/2 digit, adjustable display

Pagina 10 - Operation

Electrical Specifications Function (model) Range Accuracy % Rdg. + digits Resolution Input Protection Comments 200mV 0.1mV 250V rms 2, 20, 200V ±(0.

Pagina 11

Function Range Accuracy % rdg. + digits Resolution Input Protection Comments 2, 20, 200mA ±(0.8% + 10 digits) 0.0001,0.001,0.01mA 0.2A,250V

Pagina 12

Function Range Accuracy % rdg + digits Resolution Input Protection Comments Capacitance (MV-120) 2,20,200nF 2,20µF ±(2.5% + 3 digits) 1,10,100

Pagina 13 - Battery Replacement

Description (MV120 pictured) 1. Display release button 2. AC/DC selection on models MV110, MV120 3. Hold Button on model MV130. 4. Power ON/OFF