InsulatorMeasurementConsiderations
Insulatorsmaygetcontaminatedovertimefromamixtureofdustandmoisture.Dustand
moistureproblemslowertheresistanceofthe insulatorasthisresistanceisinparallelwiththe
insulatorresistance.Itisrecommendedthattheinsulatorbemeasuredfirstwithouttheoptional
guardlead,toverifythatthe
totalresistanceishigh.Shouldthetotalresistancenotbehigh
enough,thecontaminantsshouldberemovedortheinsulatorreplaced.Testthedirtyinsulator
forproperresistancebytestingwiththeoptionalguardlead.Note:Ifcleaningtheinsulatoris
possible,followtheprocedureofthemanufacturer.
DIRTYINSULATOR
ELECTRICALEQUIVALENT
CIRCUITDIRTYINSULATOR TYPICALTEST
Notes:
Resistanceasaresultofcontaminationcanlowerthetotalresistance.
Cleaningperiodicallycanreducesystempowerconsumption.